Third-generation moisturevariable vapour check. Maximum protection in buildings where moisture levels are critical

  • Over 59 m sd value range
  • Excellent adhesive properties
  • Ideal for exhaust insulation
  • Hydrosafe and saddle-point
  • Ideal for flat roofs

Two layer moisture-variable vapour check and airtight layer made of polyamide and polypropylene. Perfectly suited for flat roofs in timber construction; also for renovating pitched roofs with a dense outer skin. The membrane offers special protection when used on bare brickwork in winter.

Areas of application

Perfectly suited for flat roofs in timber construction; also for renovating pitched roofs with a dense outer skin. The tape offers special protection when used on bare brickwork in winter.


10 Jahre Ampack Garantie

CE 13984:2013

ISO 9001

Article numberDescriptionRoll dimensions

7640115537041

Ampatex Variano 3
with 60 lfm Ampacoll INT
1,5 m × 50 m = 75 m2
7640115536815Ampatex Variano 31,5 m × 50 m = 75 m2

7640115536983

Ampatex Variano 33,0 m × 50 m = 150 m2
Property Value Standard
Harmonised European Standard EN 13984:2013

Mass per unit area

90 g/m2

EN 1849-2

Fire behaviour

E EN 13 501-1 / EN ISO 11925-2

Brandkennziffer

5.2 VKF
Waterproofing approved at 2 kPa EN 1928, procedure A

Water vapour permeability, sD value

0,8 - 60 m EN 1931

Width of overlap

10 cm

Shear resistance of the joints

130 N EN 12 317-2

Maximum tensile strength longitudinal / transverse

180 / 125 N/5 cm

EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner

Elongation longitudinal / transverse

68 / 79 %

EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner

Resistance to tearing (nail) longitudinal / transverse

125 / 110 N

EN 12 310-1 without support liner EN 13 859-1, Appendix B, with support liner
Resistance to alkalis approved EN 1847
Air tightness airtight
Hazardous substances none
Visible defects none EN 1850-2
Values after artificial ageing

Water vapour permeability, sD value

approved EN 1296, 70°C / EN 1931
Technical data sheets
pdf Technical data sheet: Ampatex Variano 3 Technical data sheet: Ampatex Variano 3, moisture-variable vapour check and airtight layer
Declarations of performance
pdf Declaration of performance: Ampatex Variano 3 Declaration of performance: Ampatex Variano 3 1.5 x 50 m, moisture-variable vapour check and airtight layer
pdf Declaration of performance: Ampatex Variano 3 Declaration of performance: Ampatex Variano 3 3.0 x 50 m, moisture-variable vapour check and airtight layer
Product inserts
pdf Product insert: Ampatex Variano 3 Product insert: Ampatex Variano 3 1.5 x 50 m, moisture-variable vapour check and airtight layer
pdf Product insert: Ampatex Variano 3 Product insert: Ampatex Variano 3 3.0 x 50 m, moisture-variable vapour check and airtight layer
Tendering texts
pdf Tendering text: Ampatex Variano 3 Tendering text: Ampatex Variano 3, moisture-variable vapour check and airtight layer
pdf Tendering text: Ampatex Variano 3 Tendering text: Ampatex Variano 3, moisture-variable vapour check and airtight layer
Product photos
jpg Product photo: Ampatex Variano 3 Product photo: Ampatex Variano 3, moisture-variable vapour check and airtight layer

Ampatex Variano 3 is applied as an airtight layer and moisture-variable vapour check for dry interior finishing and  positioned on the warm side of the thermal insulation where it is stapled to the construction. Take care when positioning it that the membranes overlap by 10 cm and that the joints are tightly sealed with the enclosed system adhesive strip Ampacoll INT. Edge connections must be sealed with Ampacoll BK 530 or Ampacoll RA. Porous or dusty surfaces must be pretreated with Ampacoll Primax. Penetrations such as ventilation and electric pipes must be permanently sealed with Ampacoll BK 535 or Ampacoll Elektro u. Install sleeves.

pdf Dampfbremsen im winterlichen Rohbau Einbau von Dampfbremsen im winterlichen Rohbau
pdf Einblasdämmungen Verlegung von Luftdichtheitsbahnen bei Einblasdämmungen
Back to overview